detectups(8)

NAME

detectups - UPS detection/powerd configuration generator

SYNOPSIS

/sbin/detectups [tty]

DESCRIPTION

detectups monitors the serial port connected to an UPS device and will attempt to determine the method of UPS
notification of power outage. It will ask you to remove
the power cord from the wall to the UPS, or push the UPS's
test button. It will then determine what all has happened
and ask to generate a config file based on your UPS and
cable configuration. detectups needs to watch a tty with modem control properties. Please refer to the powerd doc
umentation for further information.

ARGUMENTS

Serial-Device Some serial port that is not being used by some other device, and does not share an interrupt with
any other serial port. /etc/powerd.conf

FILES

/etc/powerd.conf powerd configuration file that
detectups generates
/etc/inittab init is what actually issues the
shutdown

SEE ALSO

powerd(8), shutdown(8), wall(1), inittab(5).

AUTHOR

James Brents <James@nistix.com> (with parts of this man
page borrowed from all over the Linux community)