graid3(8)

NAME

graid3 - control utility for RAID3 devices

SYNOPSIS

graid3 label [-hnrvw] name prov prov prov ...
graid3 clear [-v] prov ...
graid3 configure [-adhnrRvwW] name
graid3 rebuild [-v] name prov
graid3 insert [-hv] -n number name prov
graid3 remove [-v] -n number name
graid3 stop [-fv] name ...
graid3 list
graid3 status
graid3 load
graid3 unload

DESCRIPTION

The graid3 utility is used for RAID3 array configuration.
After a device
is created, all components are detected and configured auto
matically.
All operations such as failure detection, stale component
detection,
rebuild of stale components, etc. are also done automatical
ly. The
graid3 utility uses on-disk metadata (the provider's last
sector) to
store all needed information.
The first argument to graid3 indicates an action to be per
formed:
label Create a RAID3 device. The last given compo
nent will con
tain parity data, whilst the others will all
contain regular data. The number of components must be
equal to 3, 5,
9, 17, etc. (2^n + 1).
Additional options include:
-h Hardcode providers' names in metadata.
-n Turn off autosynchronization of stale
components.
-r Use parity component for reading in
round-robin
fashion. Without this option the par
ity component
is not used at all for reading opera
tions when the
device is in a complete state. With
this option
specified random I/O read operations
are even 40%
faster, but sequential reads are slow
er. One cannot use this option if the -w option
is also specified.
-w Use verify reading feature. When
reading from a
device in a complete state, also read
data from the
parity component and verify the data
by comparing
XORed regular data with parity data.
If verification fails, an EIO error is returned
and the value
of the
kern.geom.raid3.stat.parity_mismatch sysctl is increased. One cannot use this op
tion if the -r
option is also specified.
clear Clear metadata on the given providers.
configure Configure the given device.

Additional options include:
-a Turn on autosynchronization of stale
components.
-d Do not hardcode providers' names in
metadata.
-h Hardcode providers' names in metadata.
-n Turn off autosynchronization of stale
components.
-r Turn on round-robin reading.
-R Turn off round-robin reading.
-w Turn on verify reading.
-W Turn off verify reading.
rebuild Rebuild the given component forcibly. If au
tosynchroniza
tion was not turned off for the given device,
this command
should be unnecessary.
insert Add the given component to the existing ar
ray, if one of
the components was removed previously with
the remove command or if one component is missing and will
not be connected again.
Additional options include:
-h Hardcode providers' names in metadata.
remove Remove the given component from the given ar
ray and clear
metadata on it.
stop Stop the given arrays.

Additional options include:
-f Stop the given array even if it is
opened.
list See geom(8).
status See geom(8).
load See geom(8).
unload See geom(8).
Additional options include:
-v Be more verbose.

EXIT STATUS

Exit status is 0 on success, and 1 if the command fails.

EXAMPLES

Use 3 disks to setup a RAID3 array (with the round-robin
reading feature). Create a file system, mount it, then unmount it and
stop device:

graid3 label -v -r data da0 da1 da2
newfs /dev/raid3/data
mount /dev/raid3/data /mnt
...
umount /mnt
graid3 stop data
graid3 unload
Create a RAID3 array, but do not use the automatic synchro
nization feature. Rebuild parity component:

graid3 label -n data da0 da1 da2
graid3 rebuild data da2
Replace one data disk with a brand new one:

graid3 remove -n 0 data
graid3 insert -n 0 data da5

SEE ALSO

geom(4), geom(8), mount(8), newfs(8), umount(8), vinum(8)

HISTORY

The graid3 utility appeared in FreeBSD 5.3.

AUTHORS

Pawel Jakub Dawidek <pjd@FreeBSD.org>

BUGS

There should be a section with an implementation descrip
tion.
Documentation for sysctls kern.geom.raid3.* is missing.
BSD August 22, 2004