comcontrol(8)
NAME
comcontrol - control a special tty device
SYNOPSIS
comcontrol special_device [dtrwait number] [drainwait number]
DESCRIPTION
- The comcontrol utility is used to examine and modify some of
- the special characteristics of the specified tty device. If no argu
- ments other than the device (or "-" for stdin) are specified, it prints the
- settings of all controllable characteristics. This usage requires only
- read access on the device. Only the superuser can change the settings.
- The following options are available:
- dtrwait number
- Set the time to wait after dropping DTR to the given
- number. The units are hundredths of a second. The default is
- 300 hundredths, i.e., 3 seconds. This option needed mainly to set
- proper recover time after modem reset.
- drainwait number
- Set the time to wait for output drain to the given
- number. The units are seconds. The default is 5 minutes, 0
- means waiting forever. This option needed mainly to specify upper
- limit of minutes to prevent modem hanging.
- The standard way to use comcontrol is to put invocations of
- it in the /etc/rc.d/serial startup script.
FILES
/dev/ttyd? dialin devices, hardwired terminals
/dev/cuad? dialout devicesSEE ALSO
HISTORY
- Originally part of cgd's com package patches, version 0.2.1,
- to 386BSD 0.1. Once controlled bidirectional capabilities. Little is
- left to control now that these capabilities are standard.
AUTHORS
- Christopher G. Demetriou
- BSD May 15, 1994