upsset.cgi(8)
NAME
upsset.cgi - Web-based UPS administration program
SYNOPSIS
upsset.cgi
NOTE
As  a  CGI program, this should be invoked through your web server.  If
you run it from the command line, it will sit there until you  give  it
input resembling a POST request.
DESCRIPTION
upsset.cgi lets you access many administrative functions within the UPS
software from your web browser.  You can  change  settings  and  invoke
instant commands where available.
CHANGING SETTINGS
Some  UPS hardware allows you to change certain variables to other values.  To see what's available, pick a UPS from the chooser  and  select
"settings", then select "View" to update the page.
You should see a list of items with the descriptions on the left side and the possible options or input spaces on the right. After changing something, be sure to "Save changes" to update the values in your UPS.
If  your  UPS  doesn't  support any read/write variables, there will be
nothing to do on this page.
Setting values in read/write variables can also be done from  the  command line with upsrw(8).
INSTANT COMMANDS
Some UPS hardware also has provisions for performing certain actions at
the user's command.  These include battery tests, battery  calibration,
front  panel  tests  (beep!)  and  more.  To access this section, do as
above, but pick "Commands" as the function.
If your UPS supports any instant commands, they will  be  listed  in  a
chooser  widget.   Pick the one you like and "Issue command" to make it
happen.
Note - some dangerous commands like "Turn  off  load"  may  not  happen
right  away.   This  is  a feature, not a bug.  The apcsmart driver and
some others require that you send this command  twice  within  a  short
window  in  order to make it happen.  This is to keep you from accidentally killing your systems by picking the wrong one.
To actually turn off the load, you have to send the command once,  then
send  it  again  after 3 seconds elapse but before 15 seconds pass.  If
you do it too quickly or slowly, you have to wait at  least  3  seconds
but not 15 seconds again.
You  can  also  invoke  instant  commands  from  the  command line with
upscmd(8).
ACCESS CONTROL
upsset will only talk to upsd(8) servers that have been defined in your
hosts.conf(8).   If  it  complains  about  "Access  to that host is not
authorized", check your hosts.conf first.
SECURITY
upsset will not run until you convince it that your CGI  directory  has
been  secured.   This is due to the possibility of someone using upsset
to try password combinations against your upsd(8) server.
See the example upsset.conf file for more information  on  how  you  do
this.   The short explanation is - if you can't lock it down, don't try
to run it.
FILES
SEE ALSO
- Internet resources:
- The NUT (Network UPS Tools) home page: http://www.networkupstools.org/